The growing challenge of energy consumption in the building sector has highlighted the necessity of adopting effective strategies to improve the thermal performance of building envelopes. Although numerous studies have investigated building industrialization and its role in reducing energy consumption, limited attention has been paid to the comparative evaluation of the energy performance of different industrialized wall systems in a real building based on validated data. Therefore, the present study aims to evaluate the impact of industrialized wall systems on energy consumption reduction in residential buildings and to identify the most efficient system for the semi-arid climate of Tehran. This applied research is based on building energy simulation. A residential building located in Tehran was selected as the case study. In the first stage, temperature and relative humidity data were collected during both summer and winter using data loggers and validated against meteorological records and ASHRAE climate data files. Subsequently, the thermal characteristics of the wall systems were analyzed using THERM software, and a building energy model was developed in DesignBuilder. To ensure the reliability of the model, simulation results were calibrated and validated using actual building energy consumption data obtained from electricity and natural gas bills. Thereafter, four industrialized wall systems, including Insulated Concrete Forms (ICF), Light Steel Framing (LSF), 3D Panel, and Tunnel Form systems, were substituted for the existing wall assemblies, and their energy performance was evaluated. The results showed that, relative to the actual baseline building whose external walls were uninsulated, the investigated industrialized wall systems reduced annual final energy consumption by approximately 60.8% to 75.8%. Among the evaluated systems, ICF achieved the lowest annual energy consumption (4052.84 kWh) and the highest reduction. However, a sensitivity scenario in which 4.5 cm of thermal insulation was added to the baseline walls showed that the energy reduction achieved by ICF decreased to approximately 34.6% relative to the insulated baseline. Therefore, the reported 75.8% reduction should be interpreted in the context of the thermal characteristics of the uninsulated reference building and the specific modeling assumptions of this study.
Keywords
Subjects